The customer is a Gujarat-based OEM. They build process and material-handling equipment — vacuum systems among it — and they integrate air-movers into packages they ship under their own name. That last part is the whole reason this duty is unforgiving.
12,000 CMH at 500 mmWC on a 50 HP coupled drive, air to about 80 °C. On paper, a moderate vacuum and material-handling duty — not a giant fan. In practice, mechanically demanding: a material-handling air-mover has to hold its operating point reliably, run after run, or the downstream process it serves drifts.
The harder problem is not one blower. It is the tenth blower matching the first. When the customer puts its own name on the finished vacuum package, unit-to-unit consistency is the whole game — the buyer of that package never sees us, only them. A blower that meets the point on the test floor but wanders from its sibling is a warranty claim waiting on someone else's letterhead.
Centrifugal blowers in both direct-drive and coupled-drive configurations, each engineered and computed to the exact duty point, then proven on the floor — not signed off from a catalogue curve.
Every unit is performance-tested in-house on our 200 HP VFD test rig, to the IS 4894 / AMCA 210 method. The test point is the same one the customer designs around, which is how the tenth unit ends up matching the first: proof, not promises.
This is not a single order. It has been multi-year, repeat OEM supply — direct-drive and coupled-drive units, order after order. An OEM that puts its name on your work does not come back unless the work holds. This customer keeps coming back.
"It is with great confidence that we recommend JITAMITRA Electro Engineering Private Limited as a supplier of centrifugal fans and blowers. We have always preferred JITAMITRA products and services for our business as they have shown consistency in quality, timely delivery, and professional integrity. JITAMITRA stands out for its precision engineering, adherence to international standards, and rigorous performance testing. Their technical expertise, transparent pricing, and responsiveness make them a trusted and strategic asset in our supply chain."— Projects lead, Vacuum Dept. · a Gujarat-based process & material-handling OEM
If you build a package and your name goes on it, tell us the duty you have to hold — flow, static, drive arrangement, air temperature — and we will engineer the blower to it and prove it on the rig before it ships. Made to order, not off a shelf.
— Mihir Kulkarni, Director, Jitamitra Electro Engineering
Engineered for Every Application.
Real dispatched fans from this duty class — nameplate-scrubbed. Representative of the work; not the customer's own unit.
Not the first blower. The tenth one matching the first. When your name goes on the finished package, unit-to-unit consistency is the whole game — the buyer of that package never sees us, only you. A blower that meets the point on the test floor but wanders from its sibling is a warranty claim waiting on someone else's letterhead.
On paper it is moderate — 12,000 CMH at 500 mmWC on a 50 HP coupled drive, air to about 80 °C, not a giant fan. In practice it is mechanically demanding: a material-handling air-mover has to hold its operating point reliably, run after run, or the downstream process it serves drifts.
Every unit is performance-tested in-house on our 200 HP VFD test rig, to the IS 4894 / AMCA 210 method. The test point is the same one you design around, which is how the tenth unit ends up matching the first. Each blower is engineered and computed to the exact duty point, then proven on the floor — not signed off from a catalogue curve.
Yes. This OEM has taken centrifugal blowers in both direct-drive and coupled-drive configurations, order after order, across multi-year repeat supply. Each is engineered to its exact duty point rather than picked off a shelf. Tell us flow, static, drive arrangement and air temperature, and we engineer the blower to it and prove it on the rig before it ships.
No. They are real dispatched fans from this duty class, nameplate-scrubbed — representative of the work, not the customer's own unit. The customer itself is identified only as a Gujarat-based process and material-handling OEM, and the testimonial is attributed to the projects lead of their vacuum department rather than to a named company.
Flow, static, gas temperature, application — or attach a spec, GA drawing or a multi-fan schedule. Engineer to engineer.
ISO 9001:2015 quality system · performance-tested to IS 4894 / ISO 5801 / AMCA 210 method · witnessed FAT on request.
*For our standard range. ATEX and special projects need 5 to 7 working days.
This site sets no cookies of its own. Google Analytics loads only if you accept. It sets two cookies, so we can see which fan topics people actually read. Decline and no analytics loads — the site works exactly the same. What we collect →