Fans we have built for furnaces, ovens and heat treatment
Home  /  Our Work  /  Furnaces, Ovens & Heat Treatment
Our Work

Fans we have built for furnaces, ovens and heat treatment

Combustion and recirculation air held steady at temperature, where shaft cooling and bearing life set the design. Every card is a real dispatched build, with its verified duty point.

Read what we engineer for furnaces, ovens and heat treatment  ·  See the whole gallery

Flow on this page runs from 120 to 84,000 CMH, against static pressure to 1,500 mmWC, at gas temperatures to 400 °C. The wheels here are backward-curved plate, backward-curved, backward-flat plate, large backward-curved, radial and aerofoil. How we choose for this duty: sizing for the cold-start spike.

Aerofoil fan built by Jitamitra for combustion and process air, 1,600 CMH at 1,100 mmWC and 40 °C
1,600CMH/1,100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 350 CMH at 800 mmWC and 40 °C
350CMH/800mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for dilution ventilation, 12,500 CMH at 50 mmWC and 40 °C
12,500CMH/50mmWC/40°C
General / dilution ventilation · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 2,100 CMH at 1,100 mmWC and 40 °C
2,100CMH/1,100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Radial fan built by Jitamitra for combustion and process air, 1,600 CMH at 1,100 mmWC and 40 °C
1,600CMH/1,100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Radial fan built by Jitamitra for combustion and process air, 1,600 CMH at 1,100 mmWC and 40 °C
1,600CMH/1,100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Radial fan built by Jitamitra for combustion and process air, 1,400 CMH at 850 mmWC and 40 °C
1,400CMH/850mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 6,380 CMH at 1,000 mmWC and 40 °C
6,380CMH/1,000mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for dilution ventilation, 12,500 CMH at 50 mmWC and 40 °C
12,500CMH/50mmWC/40°C
General / dilution ventilation · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra in furnaces, ovens and heat treatment, 12,500 CMH at 100 mmWC and 300 °C
12,500CMH/100mmWC/300°C
Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 12,500 CMH at 50 mmWC and 40 °C
12,500CMH/50mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 12,500 CMH at 50 mmWC and 40 °C
12,500CMH/50mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 24,000 CMH at 100 mmWC and 350 °C
24,000CMH/100mmWC/350°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for quench and tempering air, 5,000 CMH at 60 mmWC and 200 °C
5,000CMH/60mmWC/200°C
Quench / tempering air · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 360 CMH at 300 mmWC and 40 °C
360CMH/300mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 850 CMH at 800 mmWC and 40 °C
850CMH/800mmWC/40°C
Combustion / process air blower · Food & Beverage
Backward-curved fan built by Jitamitra for combustion and process air, 270 CMH at 375 mmWC and 30 °C
270CMH/375mmWC/30°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 650 CMH at 700 mmWC and 40 °C
650CMH/700mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 650 CMH at 700 mmWC and 40 °C
650CMH/700mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Radial fan built by Jitamitra for combustion and process air, 300 CMH at 800 mmWC and 40 °C
300CMH/800mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 1,350 CMH at 1,000 mmWC and 40 °C
1,350CMH/1,000mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 14,015 CMH at 900 mmWC and 20 °C
14,015CMH/900mmWC/20°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 14,015 CMH at 900 mmWC and 20 °C
14,015CMH/900mmWC/20°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 600 CMH at 700 mmWC and 30 °C
600CMH/700mmWC/30°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 600 CMH at 700 mmWC and 30 °C
600CMH/700mmWC/30°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 3,400 CMH at 150 mmWC and 150 °C
3,400CMH/150mmWC/150°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 3,400 CMH at 150 mmWC and 150 °C
3,400CMH/150mmWC/150°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 522 CMH at 762 mmWC and 40 °C
522CMH/762mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 522 CMH at 762 mmWC and 40 °C
522CMH/762mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for dilution ventilation, 4,800 CMH at 80 mmWC and 40 °C
4,800CMH/80mmWC/40°C
General / dilution ventilation · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for dilution ventilation, 4,800 CMH at 80 mmWC and 40 °C
4,800CMH/80mmWC/40°C
General / dilution ventilation · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 1,615 CMH at 1,016 mmWC and 40 °C
1,615CMH/1,016mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 1,615 CMH at 1,016 mmWC and 40 °C
1,615CMH/1,016mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for combustion and process air, 4,350 CMH at 350 mmWC and 40 °C
4,350CMH/350mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for combustion and process air, 4,350 CMH at 350 mmWC and 40 °C
4,350CMH/350mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for spray and fluid-bed drying, 5,000 CMH at 50 mmWC and 180 °C
5,000CMH/50mmWC/180°C
Drying (spray / fluid-bed / flash) · Automotive & Paint
Backward-flat plate fan built by Jitamitra for spray and fluid-bed drying, 5,000 CMH at 50 mmWC and 180 °C
5,000CMH/50mmWC/180°C
Drying (spray / fluid-bed / flash) · Automotive & Paint
Backward-curved fan built by Jitamitra for combustion and process air in furnaces, ovens and heat treatment
Duty on request
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air in furnaces, ovens and heat treatment
Duty on request
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for combustion and process air, 4,350 CMH at 350 mmWC and 40 °C
4,350CMH/350mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for combustion and process air, 4,350 CMH at 350 mmWC and 40 °C
4,350CMH/350mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for ATEX paint-booth exhaust, 84,000 CMH at 105 mmWC and 40 °C
84,000CMH/105mmWC/40°C
ATEX / paint-booth exhaust · Automotive & Paint
Backward-curved fan built by Jitamitra for ATEX paint-booth exhaust, 84,000 CMH at 105 mmWC and 40 °C
84,000CMH/105mmWC/40°C
ATEX / paint-booth exhaust · Automotive & Paint
Backward-curved fan built by Jitamitra for combustion and process air, 552 CMH at 1,118 mmWC and 40 °C
552CMH/1,118mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 552 CMH at 1,118 mmWC and 40 °C
552CMH/1,118mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for combustion and process air, 14,680 CMH at 216 mmWC and 90 °C
14,680CMH/216mmWC/90°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for combustion and process air, 14,680 CMH at 216 mmWC and 90 °C
14,680CMH/216mmWC/90°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 400 CMH at 800 mmWC and 40 °C
400CMH/800mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 400 CMH at 800 mmWC and 40 °C
400CMH/800mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 2,990 CMH at 950 mmWC and 40 °C
2,990CMH/950mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 2,990 CMH at 950 mmWC and 40 °C
2,990CMH/950mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air in furnaces, ovens and heat treatment
Duty on request
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air in furnaces, ovens and heat treatment
Duty on request
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Radial fan built by Jitamitra for combustion and process air, 300 CMH at 100 mmWC and 40 °C
300CMH/100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Radial fan built by Jitamitra for combustion and process air, 300 CMH at 100 mmWC and 40 °C
300CMH/100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 300 CMH at 800 mmWC and 40 °C
300CMH/800mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 300 CMH at 800 mmWC and 40 °C
300CMH/800mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 500 CMH at 800 mmWC and 30 °C
500CMH/800mmWC/30°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 500 CMH at 800 mmWC and 30 °C
500CMH/800mmWC/30°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 1,000 CMH at 300 mmWC and 20 °C
1,000CMH/300mmWC/20°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 1,700 CMH at 1,050 mmWC and 40 °C
1,700CMH/1,050mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 1,700 CMH at 1,050 mmWC and 40 °C
1,700CMH/1,050mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 18,000 CMH at 100 mmWC and 250 °C
18,000CMH/100mmWC/250°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 18,000 CMH at 100 mmWC and 250 °C
18,000CMH/100mmWC/250°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 425 CMH at 275 mmWC and 40 °C
425CMH/275mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 425 CMH at 275 mmWC and 40 °C
425CMH/275mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Impeller replacement & redesign (any make) job by Jitamitra for combustion and process air
Impeller replacement & redesign (any make)
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 6,263 CMH at 1,300 mmWC and 40 °C
6,263CMH/1,300mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 6,263 CMH at 1,300 mmWC and 40 °C
6,263CMH/1,300mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 6,263 CMH at 1,300 mmWC and 40 °C
6,263CMH/1,300mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 5,799 CMH at 75 mmWC and 40 °C
5,799CMH/75mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 5,799 CMH at 75 mmWC and 40 °C
5,799CMH/75mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 12,500 CMH at 50 mmWC and 40 °C
12,500CMH/50mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 12,500 CMH at 50 mmWC and 40 °C
12,500CMH/50mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 12,500 CMH at 50 mmWC and 40 °C
12,500CMH/50mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 12,500 CMH at 50 mmWC and 40 °C
12,500CMH/50mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for spray and fluid-bed drying, 8,500 CMH at 150 mmWC and 200 °C
8,500CMH/150mmWC/200°C
Drying (spray / fluid-bed / flash) · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for spray and fluid-bed drying, 8,500 CMH at 150 mmWC and 200 °C
8,500CMH/150mmWC/200°C
Drying (spray / fluid-bed / flash) · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 4,000 CMH at 200 mmWC and 40 °C
4,000CMH/200mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 4,000 CMH at 200 mmWC and 40 °C
4,000CMH/200mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for spray and fluid-bed drying, 8,500 CMH at 150 mmWC and 200 °C
8,500CMH/150mmWC/200°C
Drying (spray / fluid-bed / flash) · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for spray and fluid-bed drying, 8,500 CMH at 150 mmWC and 200 °C
8,500CMH/150mmWC/200°C
Drying (spray / fluid-bed / flash) · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 2,550 CMH at 150 mmWC and 150 °C
2,550CMH/150mmWC/150°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 2,990 CMH at 950 mmWC and 40 °C
2,990CMH/950mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 2,990 CMH at 950 mmWC and 40 °C
2,990CMH/950mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 360 CMH at 300 mmWC and 40 °C
360CMH/300mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 360 CMH at 300 mmWC and 40 °C
360CMH/300mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 1,300 CMH at 480 mmWC and 30 °C
1,300CMH/480mmWC/30°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 1,300 CMH at 480 mmWC and 30 °C
1,300CMH/480mmWC/30°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 360 CMH at 300 mmWC and 40 °C
360CMH/300mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 360 CMH at 300 mmWC and 40 °C
360CMH/300mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 300 CMH at 100 mmWC and 40 °C
300CMH/100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 300 CMH at 100 mmWC and 40 °C
300CMH/100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 300 CMH at 100 mmWC and 40 °C
300CMH/100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 300 CMH at 100 mmWC and 40 °C
300CMH/100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for forced draught, 1,200 CMH at 80 mmWC and 40 °C
1,200CMH/80mmWC/40°C
Forced Draft (FD) · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for forced draught, 1,200 CMH at 80 mmWC and 40 °C
1,200CMH/80mmWC/40°C
Forced Draft (FD) · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for combustion and process air, 6,650 CMH at 510 mmWC and 40 °C
6,650CMH/510mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for combustion and process air, 6,650 CMH at 510 mmWC and 40 °C
6,650CMH/510mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 3,400 CMH at 150 mmWC and 150 °C
3,400CMH/150mmWC/150°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 3,400 CMH at 150 mmWC and 150 °C
3,400CMH/150mmWC/150°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for spray and fluid-bed drying, 2,000 CMH at 100 mmWC and 40 °C
2,000CMH/100mmWC/40°C
Drying (spray / fluid-bed / flash) · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for spray and fluid-bed drying, 2,000 CMH at 100 mmWC and 40 °C
2,000CMH/100mmWC/40°C
Drying (spray / fluid-bed / flash) · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 400 CMH at 1,000 mmWC and 20 °C
400CMH/1,000mmWC/20°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 400 CMH at 1,000 mmWC and 20 °C
400CMH/1,000mmWC/20°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 300 CMH at 100 mmWC and 40 °C
300CMH/100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 300 CMH at 100 mmWC and 40 °C
300CMH/100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 5,085 CMH at 60 mmWC and 50 °C
5,085CMH/60mmWC/50°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 5,085 CMH at 60 mmWC and 50 °C
5,085CMH/60mmWC/50°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for dilution ventilation, 4,200 CMH at 100 mmWC and 40 °C
4,200CMH/100mmWC/40°C
General / dilution ventilation · Automotive & Paint
Backward-curved plate fan built by Jitamitra for dilution ventilation, 4,200 CMH at 100 mmWC and 40 °C
4,200CMH/100mmWC/40°C
General / dilution ventilation · Automotive & Paint
Backward-curved fan built by Jitamitra for combustion and process air, 300 CMH at 100 mmWC and 40 °C
300CMH/100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 300 CMH at 100 mmWC and 40 °C
300CMH/100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 1,600 CMH at 1,100 mmWC and 40 °C
1,600CMH/1,100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 1,600 CMH at 1,100 mmWC and 40 °C
1,600CMH/1,100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 1,600 CMH at 1,100 mmWC and 40 °C
1,600CMH/1,100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 1,600 CMH at 1,100 mmWC and 40 °C
1,600CMH/1,100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 5,085 CMH at 60 mmWC and 50 °C
5,085CMH/60mmWC/50°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 5,085 CMH at 60 mmWC and 50 °C
5,085CMH/60mmWC/50°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for kiln and furnace exhaust, 73,000 CMH at 350 mmWC and 250 °C
73,000CMH/350mmWC/250°C
Kiln / furnace exhaust · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for kiln and furnace exhaust, 73,000 CMH at 350 mmWC and 250 °C
73,000CMH/350mmWC/250°C
Kiln / furnace exhaust · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for combustion and process air, 34,000 CMH at 328 mmWC and 40 °C
34,000CMH/328mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for combustion and process air, 34,000 CMH at 328 mmWC and 40 °C
34,000CMH/328mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for spray and fluid-bed drying, 46,000 CMH at 115 mmWC and 400 °C
46,000CMH/115mmWC/400°C
Drying (spray / fluid-bed / flash) · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for spray and fluid-bed drying, 46,000 CMH at 115 mmWC and 400 °C
46,000CMH/115mmWC/400°C
Drying (spray / fluid-bed / flash) · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for spray and fluid-bed drying, 46,000 CMH at 115 mmWC and 400 °C
46,000CMH/115mmWC/400°C
Drying (spray / fluid-bed / flash) · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 4,000 CMH at 950 mmWC and 40 °C
4,000CMH/950mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 4,000 CMH at 950 mmWC and 40 °C
4,000CMH/950mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 935 CMH at 1,000 mmWC and 40 °C
935CMH/1,000mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 935 CMH at 1,000 mmWC and 40 °C
935CMH/1,000mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for kiln and furnace exhaust, 23,000 CMH at 200 mmWC and 250 °C
23,000CMH/200mmWC/250°C
Kiln / furnace exhaust · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for kiln and furnace exhaust, 23,000 CMH at 200 mmWC and 250 °C
23,000CMH/200mmWC/250°C
Kiln / furnace exhaust · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for ATEX paint-booth exhaust, 10,000 CMH at 45 mmWC and 120 °C
10,000CMH/45mmWC/120°C
ATEX / paint-booth exhaust · Automotive & Paint
Backward-curved fan built by Jitamitra for ATEX paint-booth exhaust, 10,000 CMH at 45 mmWC and 120 °C
10,000CMH/45mmWC/120°C
ATEX / paint-booth exhaust · Automotive & Paint
Backward-flat plate fan built by Jitamitra for combustion and process air, 50,000 CMH at 200 mmWC and 250 °C
50,000CMH/200mmWC/250°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for combustion and process air, 50,000 CMH at 200 mmWC and 250 °C
50,000CMH/200mmWC/250°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for forced draught, 1,105 CMH at 305 mmWC and 40 °C
1,105CMH/305mmWC/40°C
Forced Draft (FD) · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for forced draught, 1,105 CMH at 305 mmWC and 40 °C
1,105CMH/305mmWC/40°C
Forced Draft (FD) · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for spray and fluid-bed drying, 46,000 CMH at 115 mmWC and 400 °C
46,000CMH/115mmWC/400°C
Drying (spray / fluid-bed / flash) · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for spray and fluid-bed drying, 46,000 CMH at 115 mmWC and 400 °C
46,000CMH/115mmWC/400°C
Drying (spray / fluid-bed / flash) · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for spray and fluid-bed drying, 46,000 CMH at 115 mmWC and 400 °C
46,000CMH/115mmWC/400°C
Drying (spray / fluid-bed / flash) · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for spray and fluid-bed drying, 46,000 CMH at 115 mmWC and 400 °C
46,000CMH/115mmWC/400°C
Drying (spray / fluid-bed / flash) · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air in furnaces, ovens and heat treatment
Duty on request
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air in furnaces, ovens and heat treatment
Duty on request
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air in furnaces, ovens and heat treatment
Duty on request
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air in furnaces, ovens and heat treatment
Duty on request
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air in furnaces, ovens and heat treatment
Duty on request
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air in furnaces, ovens and heat treatment
Duty on request
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air in furnaces, ovens and heat treatment
Duty on request
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air in furnaces, ovens and heat treatment
Duty on request
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for combustion and process air in furnaces, ovens and heat treatment
Duty on request
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for combustion and process air in furnaces, ovens and heat treatment
Duty on request
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 12,500 CMH at 50 mmWC and 40 °C
12,500CMH/50mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 1,600 CMH at 1,000 mmWC and 20 °C
1,600CMH/1,000mmWC/20°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 12,500 CMH at 50 mmWC and 40 °C
12,500CMH/50mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 2,400 CMH at 100 mmWC and 30 °C
2,400CMH/100mmWC/30°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 12,500 CMH at 50 mmWC and 40 °C
12,500CMH/50mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 12,500 CMH at 50 mmWC and 40 °C
12,500CMH/50mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Large backward-curved fan built by Jitamitra for combustion and process air, 2,100 CMH at 1,100 mmWC and 40 °C
2,100CMH/1,100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air in furnaces, ovens and heat treatment
Duty on request
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 425 CMH at 275 mmWC and 40 °C
425CMH/275mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 300 CMH at 800 mmWC and 40 °C
300CMH/800mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 1,600 CMH at 900 mmWC and 40 °C
1,600CMH/900mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for kiln and furnace exhaust, 43,000 CMH at 230 mmWC and 250 °C
43,000CMH/230mmWC/250°C
Kiln / furnace exhaust · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 23,500 CMH at 190 mmWC and 40 °C
23,500CMH/190mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Large backward-curved fan built by Jitamitra for combustion and process air, 2,100 CMH at 1,100 mmWC and 40 °C
2,100CMH/1,100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Large backward-curved fan built by Jitamitra for combustion and process air, 2,100 CMH at 1,100 mmWC and 40 °C
2,100CMH/1,100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 425 CMH at 275 mmWC and 40 °C
425CMH/275mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 425 CMH at 275 mmWC and 40 °C
425CMH/275mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 900 CMH at 1,100 mmWC and 40 °C
900CMH/1,100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 12,500 CMH at 50 mmWC and 40 °C
12,500CMH/50mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 2,550 CMH at 150 mmWC and 150 °C
2,550CMH/150mmWC/150°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 650 CMH at 700 mmWC and 40 °C
650CMH/700mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for forced draught, 1,200 CMH at 80 mmWC and 40 °C
1,200CMH/80mmWC/40°C
Forced Draft (FD) · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 12,500 CMH at 50 mmWC and 40 °C
12,500CMH/50mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for forced draught, 1,200 CMH at 80 mmWC and 40 °C
1,200CMH/80mmWC/40°C
Forced Draft (FD) · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 650 CMH at 700 mmWC and 40 °C
650CMH/700mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Radial fan built by Jitamitra for combustion and process air, 1,524 CMH at 880 mmWC and 40 °C
1,524CMH/880mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 12,500 CMH at 50 mmWC and 40 °C
12,500CMH/50mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 10,800 CMH at 50 mmWC and 40 °C
10,800CMH/50mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Large backward-curved fan built by Jitamitra for spray and fluid-bed drying, 550 CMH at 250 mmWC and 200 °C
550CMH/250mmWC/200°C
Drying (spray / fluid-bed / flash) · Automotive & Paint
Backward-curved fan built by Jitamitra for combustion and process air, 12,500 CMH at 50 mmWC and 40 °C
12,500CMH/50mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 550 CMH at 700 mmWC and 30 °C
550CMH/700mmWC/30°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 1,600 CMH at 1,000 mmWC and 20 °C
1,600CMH/1,000mmWC/20°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Large backward-curved fan built by Jitamitra for combustion and process air, 2,100 CMH at 1,100 mmWC and 20 °C
2,100CMH/1,100mmWC/20°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 1,600 CMH at 1,000 mmWC and 20 °C
1,600CMH/1,000mmWC/20°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 10,800 CMH at 50 mmWC and 40 °C
10,800CMH/50mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 1,500 CMH at 1,100 mmWC and 20 °C
1,500CMH/1,100mmWC/20°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 300 CMH at 100 mmWC and 40 °C
300CMH/100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 3,400 CMH at 150 mmWC and 150 °C
3,400CMH/150mmWC/150°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 360 CMH at 300 mmWC and 40 °C
360CMH/300mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air in furnaces, ovens and heat treatment
Duty on request
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 383 CMH at 1,000 mmWC and 40 °C
383CMH/1,000mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 425 CMH at 1,016 mmWC and 40 °C
425CMH/1,016mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air in furnaces, ovens and heat treatment
Duty on request
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Centrifugal fan built by Jitamitra in furnaces, ovens and heat treatment
Duty on request
Furnaces, Ovens & Heat Treatment
Centrifugal fan built by Jitamitra for combustion and process air in furnaces, ovens and heat treatment
Duty on request
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 350 CMH at 800 mmWC and 40 °C
350CMH/800mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for spray and fluid-bed drying, 3,600 CMH at 100 mmWC and 30 °C
3,600CMH/100mmWC/30°C
Drying (spray / fluid-bed / flash) · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 6,350 CMH at 1,000 mmWC and 40 °C
6,350CMH/1,000mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 383 CMH at 1,000 mmWC and 40 °C
383CMH/1,000mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 300 CMH at 100 mmWC and 40 °C
300CMH/100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 3,400 CMH at 150 mmWC and 150 °C
3,400CMH/150mmWC/150°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 1,700 CMH at 1,000 mmWC and 20 °C
1,700CMH/1,000mmWC/20°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 3,000 CMH at 1,200 mmWC and 70 °C
3,000CMH/1,200mmWC/70°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for dust extraction in pollution control OEMs, 2,000 CMH at 1,050 mmWC and 40 °C
2,000CMH/1,050mmWC/40°C
Dust extraction (dirty side) · Pollution Control / APC OEM
Backward-curved plate fan built by Jitamitra for dust extraction in pollution control OEMs, 1,700 CMH at 900 mmWC and 40 °C
1,700CMH/900mmWC/40°C
Dust extraction (dirty side) · Pollution Control / APC OEM
Backward-curved fan built by Jitamitra for ATEX paint-booth exhaust, 7,000 CMH at 50 mmWC and 50 °C
7,000CMH/50mmWC/50°C
ATEX / paint-booth exhaust · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 300 CMH at 100 mmWC and 40 °C
300CMH/100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 1,000 CMH at 850 mmWC and 40 °C
1,000CMH/850mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for forced draught, 1,200 CMH at 80 mmWC and 40 °C
1,200CMH/80mmWC/40°C
Forced Draft (FD) · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for combustion and process air, 2,400 CMH at 70 mmWC and 250 °C
2,400CMH/70mmWC/250°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for combustion and process air, 2,400 CMH at 70 mmWC and 250 °C
2,400CMH/70mmWC/250°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for combustion and process air, 10,000 CMH at 350 mmWC and 40 °C
10,000CMH/350mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air in furnaces, ovens and heat treatment
Duty on request
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 1,600 CMH at 1,100 mmWC and 40 °C
1,600CMH/1,100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 480 CMH at 810 mmWC and 40 °C
480CMH/810mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 750 CMH at 1,000 mmWC and 20 °C
750CMH/1,000mmWC/20°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 360 CMH at 300 mmWC and 40 °C
360CMH/300mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 350 CMH at 800 mmWC and 40 °C
350CMH/800mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 300 CMH at 100 mmWC and 40 °C
300CMH/100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air in furnaces, ovens and heat treatment
Duty on request
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 360 CMH at 300 mmWC and 40 °C
360CMH/300mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 120 CMH at 550 mmWC and 40 °C
120CMH/550mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 360 CMH at 300 mmWC and 40 °C
360CMH/300mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 3,400 CMH at 150 mmWC and 150 °C
3,400CMH/150mmWC/150°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 300 CMH at 100 mmWC and 40 °C
300CMH/100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 425 CMH at 275 mmWC and 40 °C
425CMH/275mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 1,000 CMH at 850 mmWC and 40 °C
1,000CMH/850mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 425 CMH at 275 mmWC and 40 °C
425CMH/275mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 360 CMH at 300 mmWC and 40 °C
360CMH/300mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 3,400 CMH at 150 mmWC and 150 °C
3,400CMH/150mmWC/150°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for combustion and process air, 3,500 CMH at 200 mmWC and 30 °C
3,500CMH/200mmWC/30°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for forced draught, 1,200 CMH at 425 mmWC and 30 °C
1,200CMH/425mmWC/30°C
Forced Draft (FD) · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 150 CMH at 600 mmWC and 40 °C
150CMH/600mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 360 CMH at 300 mmWC and 40 °C
360CMH/300mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 3,400 CMH at 150 mmWC and 150 °C
3,400CMH/150mmWC/150°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 300 CMH at 100 mmWC and 40 °C
300CMH/100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 383 CMH at 1,000 mmWC and 40 °C
383CMH/1,000mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 400 CMH at 800 mmWC and 40 °C
400CMH/800mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Centrifugal fan built by Jitamitra in furnaces, ovens and heat treatment
Duty on request
Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 1,600 CMH at 1,100 mmWC and 40 °C
1,600CMH/1,100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for combustion and process air, 10,000 CMH at 50 mmWC and 20 °C
10,000CMH/50mmWC/20°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for ATEX paint-booth exhaust, 10,000 CMH at 45 mmWC and 120 °C
10,000CMH/45mmWC/120°C
ATEX / paint-booth exhaust · Automotive & Paint
Backward-curved fan built by Jitamitra for ATEX paint-booth exhaust in automotive paint shops, 6,000 CMH at 40 mmWC and 45 °C
6,000CMH/40mmWC/45°C
ATEX / paint-booth exhaust · Automotive & Paint
Backward-curved fan built by Jitamitra for combustion and process air, 400 CMH at 620 mmWC and 40 °C
400CMH/620mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for dust extraction in pollution control OEMs, 2,700 CMH at 900 mmWC and 40 °C
2,700CMH/900mmWC/40°C
Dust extraction (dirty side) · Pollution Control / APC OEM
Backward-curved fan built by Jitamitra for combustion and process air, 360 CMH at 300 mmWC and 40 °C
360CMH/300mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 2,550 CMH at 150 mmWC and 150 °C
2,550CMH/150mmWC/150°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 3,400 CMH at 150 mmWC and 150 °C
3,400CMH/150mmWC/150°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 360 CMH at 300 mmWC and 40 °C
360CMH/300mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 360 CMH at 300 mmWC and 40 °C
360CMH/300mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 360 CMH at 300 mmWC and 40 °C
360CMH/300mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 425 CMH at 275 mmWC and 40 °C
425CMH/275mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 300 CMH at 800 mmWC and 40 °C
300CMH/800mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 2,550 CMH at 150 mmWC and 150 °C
2,550CMH/150mmWC/150°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for ATEX paint-booth exhaust, 8,000 CMH at 1,500 mmWC and 70 °C
8,000CMH/1,500mmWC/70°C
ATEX / paint-booth exhaust · Furnaces, Ovens & Heat Treatment
Centrifugal fan built by Jitamitra for combustion and process air in foundries and casting
Duty on request
Combustion / process air blower · Foundry & Casting
Backward-flat plate fan built by Jitamitra for seal, cooling and booster air, 15,000 CMH at 50 mmWC and 40 °C
15,000CMH/50mmWC/40°C
Seal / cooling / booster air · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 360 CMH at 300 mmWC and 40 °C
360CMH/300mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 400 CMH at 800 mmWC and 40 °C
400CMH/800mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for combustion and process air, 2,481 CMH at 50 mmWC and 30 °C
2,481CMH/50mmWC/30°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for combustion and process air, 2,481 CMH at 50 mmWC and 30 °C
2,481CMH/50mmWC/30°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 360 CMH at 300 mmWC and 40 °C
360CMH/300mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 360 CMH at 300 mmWC and 40 °C
360CMH/300mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for ATEX paint-booth exhaust, 8,000 CMH at 50 mmWC and 30 °C
8,000CMH/50mmWC/30°C
ATEX / paint-booth exhaust · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for spray and fluid-bed drying, 10,000 CMH at 50 mmWC and 50 °C
10,000CMH/50mmWC/50°C
Drying (spray / fluid-bed / flash) · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 550 CMH at 850 mmWC
550CMH/850mmWC/0°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Radial fan built by Jitamitra for combustion and process air in furnaces, ovens and heat treatment
Duty on request
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Radial fan built by Jitamitra for combustion and process air, 2,157 CMH at 1,200 mmWC and 20 °C
2,157CMH/1,200mmWC/20°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 2,250 CMH at 900 mmWC and 40 °C
2,250CMH/900mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 2,000 CMH at 100 mmWC and 40 °C
2,000CMH/100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 300 CMH at 100 mmWC and 40 °C
300CMH/100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 7,000 CMH at 450 mmWC and 40 °C
7,000CMH/450mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 1,200 CMH at 900 mmWC and 30 °C
1,200CMH/900mmWC/30°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for dilution ventilation, 4,000 CMH at 60 mmWC and 40 °C
4,000CMH/60mmWC/40°C
General / dilution ventilation · Surface Coating & Plating
Backward-curved fan built by Jitamitra for combustion and process air, 150 CMH at 550 mmWC and 40 °C
150CMH/550mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 425 CMH at 275 mmWC and 40 °C
425CMH/275mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 4,700 CMH at 90 mmWC and 40 °C
4,700CMH/90mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for combustion and process air, 360 CMH at 300 mmWC and 40 °C
360CMH/300mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 300 CMH at 100 mmWC and 40 °C
300CMH/100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for quench and tempering air, 5,000 CMH at 60 mmWC and 200 °C
5,000CMH/60mmWC/200°C
Quench / tempering air · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air in furnaces, ovens and heat treatment
Duty on request
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 722 CMH at 1,016 mmWC and 40 °C
722CMH/1,016mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 1,615 CMH at 1,016 mmWC and 40 °C
1,615CMH/1,016mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 1,360 CMH at 1,000 mmWC and 40 °C
1,360CMH/1,000mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 1,360 CMH at 1,000 mmWC and 40 °C
1,360CMH/1,000mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 620 CMH at 1,118 mmWC and 40 °C
620CMH/1,118mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 300 CMH at 100 mmWC and 40 °C
300CMH/100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air in furnaces, ovens and heat treatment
Duty on request
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 1,143 CMH at 1,000 mmWC and 20 °C
1,143CMH/1,000mmWC/20°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 400 CMH at 700 mmWC and 20 °C
400CMH/700mmWC/20°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 808 CMH at 1,016 mmWC and 40 °C
808CMH/1,016mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 1,600 CMH at 1,100 mmWC and 40 °C
1,600CMH/1,100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for spray and fluid-bed drying, 5,000 CMH at 50 mmWC and 180 °C
5,000CMH/50mmWC/180°C
Drying (spray / fluid-bed / flash) · Automotive & Paint
Backward-curved fan built by Jitamitra for combustion and process air, 552 CMH at 1,118 mmWC and 40 °C
552CMH/1,118mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 2,000 CMH at 50 mmWC and 60 °C
2,000CMH/50mmWC/60°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 4,500 CMH at 1,200 mmWC and 20 °C
4,500CMH/1,200mmWC/20°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 4,500 CMH at 1,400 mmWC and 20 °C
4,500CMH/1,400mmWC/20°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 6,000 CMH at 1,200 mmWC and 20 °C
6,000CMH/1,200mmWC/20°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 3,400 CMH at 150 mmWC and 150 °C
3,400CMH/150mmWC/150°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for spray and fluid-bed drying, 2,400 CMH at 100 mmWC and 30 °C
2,400CMH/100mmWC/30°C
Drying (spray / fluid-bed / flash) · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for spray and fluid-bed drying, 4,800 CMH at 140 mmWC and 130 °C
4,800CMH/140mmWC/130°C
Drying (spray / fluid-bed / flash) · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 1,600 CMH at 900 mmWC and 20 °C
1,600CMH/900mmWC/20°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 40,000 CMH at 100 mmWC and 350 °C
40,000CMH/100mmWC/350°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air in furnaces, ovens and heat treatment
Duty on request
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air in furnaces, ovens and heat treatment
Duty on request
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Radial fan built by Jitamitra for combustion and process air, 300 CMH at 100 mmWC and 40 °C
300CMH/100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Radial fan built by Jitamitra for combustion and process air, 1,000 CMH at 1,000 mmWC and 20 °C
1,000CMH/1,000mmWC/20°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 700 CMH at 300 mmWC and 40 °C
700CMH/300mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for ATEX paint-booth exhaust, 32,600 CMH at 75 mmWC and 200 °C
32,600CMH/75mmWC/200°C
ATEX / paint-booth exhaust · Automotive & Paint
Backward-curved fan built by Jitamitra for combustion and process air, 774 CMH at 1,016 mmWC and 40 °C
774CMH/1,016mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra in furnaces, ovens and heat treatment, 57,200 CMH at 250 mmWC and 350 °C
57,200CMH/250mmWC/350°C
Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 3,300 CMH at 450 mmWC and 40 °C
3,300CMH/450mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra in furnaces, ovens and heat treatment, 16,300 CMH at 110 mmWC and 400 °C
16,300CMH/110mmWC/400°C
Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra in furnaces, ovens and heat treatment, 16,300 CMH at 110 mmWC and 400 °C
16,300CMH/110mmWC/400°C
Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra in furnaces, ovens and heat treatment, 16,300 CMH at 110 mmWC and 400 °C
16,300CMH/110mmWC/400°C
Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra in furnaces, ovens and heat treatment, 16,300 CMH at 110 mmWC and 400 °C
16,300CMH/110mmWC/400°C
Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra in furnaces, ovens and heat treatment, 16,300 CMH at 110 mmWC and 400 °C
16,300CMH/110mmWC/400°C
Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra in furnaces, ovens and heat treatment, 16,300 CMH at 110 mmWC and 400 °C
16,300CMH/110mmWC/400°C
Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for combustion and process air, 2,550 CMH at 130 mmWC and 100 °C
2,550CMH/130mmWC/100°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 3,000 CMH at 1,200 mmWC and 20 °C
3,000CMH/1,200mmWC/20°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Radial fan built by Jitamitra for spray and fluid-bed drying in furnaces, ovens and heat treatment
Duty on request
Drying (spray / fluid-bed / flash) · Furnaces, Ovens & Heat Treatment
Radial fan built by Jitamitra for spray and fluid-bed drying in furnaces, ovens and heat treatment
Duty on request
Drying (spray / fluid-bed / flash) · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for combustion and process air, 8,100 CMH at 400 mmWC and 20 °C
8,100CMH/400mmWC/20°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-flat plate fan built by Jitamitra for seal, cooling and booster air, 16,500 CMH at 50 mmWC and 40 °C
16,500CMH/50mmWC/40°C
Seal / cooling / booster air · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 5,085 CMH at 60 mmWC and 50 °C
5,085CMH/60mmWC/50°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 300 CMH at 100 mmWC and 40 °C
300CMH/100mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 1,615 CMH at 1,016 mmWC and 40 °C
1,615CMH/1,016mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved plate fan built by Jitamitra for combustion and process air, 850 CMH at 800 mmWC and 40 °C
850CMH/800mmWC/40°C
Combustion / process air blower · Food & Beverage
Backward-curved fan built by Jitamitra for combustion and process air, 1,500 CMH at 914 mmWC and 40 °C
1,500CMH/914mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment
Backward-curved fan built by Jitamitra for combustion and process air, 760 CMH at 711 mmWC and 40 °C
760CMH/711mmWC/40°C
Combustion / process air blower · Furnaces, Ovens & Heat Treatment

Duty points are the customer's design conditions, verified from our manufacturing records (GA drawings / M.O. sheets). Customer names and identifying marks are withheld.

Seen a fan like yours? Tell us your duty point.

Give us the flow, static pressure, gas and temperature — our engineers size it and quote in 3 to 5 working days.*

Get a quote