Same fan, thinner air: correcting a duty for altitude, heat and suction

Why the same fan makes less pressure in hot gas, at altitude or under suction — and how to refer a duty to standard air before you read a curve.

Reviewed by Jitamitra application engineering

Share on LinkedIn
In short

How do I correct a fan duty for altitude, temperature and inlet suction?

Work out the gas density at the fan inlet from the site’s barometric pressure, the inlet suction and the gas temperature. Convert any normal or mass flow to actual m³/h, then scale the fan static pressure by 1.2 divided by that density to read the standard-air curve. The flow stays the same; pressure and power scale with density; the construction is still chosen for the real temperature.

Every fan curve in a catalogue, and every test result, is quoted at one air density. Almost no real duty runs at it. A fan in a hot-gas line, on a plant several hundred metres above sea level, pulling hard through a filter, sees gas noticeably thinner than the curve assumes — and the same fan then makes less pressure and draws less power than the curve says. This note shows how we refer every duty to standard air before it is compared with a curve, and the arithmetic behind it.

A duty is three numbers, not two

A duty is the actual volume at the fan inlet, the fan static pressure, and the density of the gas at the inlet. The density carries everything else: gas temperature, the site’s elevation (its barometric pressure), the suction at the fan inlet, humidity and gas composition. The elevation that matters is the site the fan is going to, so we ask for it on every enquiry rather than assume it from where the order comes from — one customer’s fans often go to several plants.

Standard air, and why every curve uses it

Standard air is 1.2 kg/m³ at a barometric pressure of 101.325 kPa, roughly 20 °C at sea level. It is the basis AMCA 99 defines and the one fan curves and test results are quoted on. To compare a real duty with a curve, refer the duty to that density first.

What changes with density, and what does not

At a given speed a centrifugal fan is a constant-volume machine: it moves the same actual m³/h whatever the density. The pressure it develops and the power it draws both vary in direct proportion to density. So:

Two orders of work follow. A flow given in normal or mass terms (Nm³/h, kg/h) is converted to actual inlet m³/h before anything else. Then the pressure is scaled to standard air and the fan is read off the curve at that pressure.

Altitude on its own

Elevation alone takes a real share off the curve, before any heat or suction. Dry air on a 40 °C day:

Site elevationBarometric pressure, kPaAir density at 40 °C, kg/m³Share of standard air
Sea level101.331.12794%
216 m (Delhi)98.761.09992%
555 m94.831.05588%
920 m (Bengaluru)90.751.01084%

A fan selected at standard air for a 40 °C plant at 920 m develops only about 84% of the pressure its curve shows. That gap is why the elevation question is on every enquiry.

Worked example: hot gas, at altitude, under suction

A process exhaust stated as 50,000 Nm³/h of gas at 200 °C, with 400 mmWC of suction at the fan inlet, on a site 555 m above sea level, needing 300 mmWC fan static pressure at site:

StepValue
Stated duty50,000 Nm³/h at 0 °C and 101.325 kPa; gas at 200 °C; 400 mmWC suction at the fan inlet; site at 555 m; 300 mmWC fan static pressure at site
Barometric pressure at 555 m94.83 kPa
Absolute pressure at the fan inlet94.83 − 3.92 = 90.91 kPa
Actual inlet volume50,000 × (473.15 / 273.15) × (101.325 / 90.91) = 96,532 m³/h
Gas density at the fan inlet0.669 kg/m³
Static pressure to read on a standard-air curve300 × 1.2 / 0.669 = 538 mmWC
Cold start at 30 °C, same site and suction1.045 kg/m³, so 1.56 × the hot running power

Read on the stated normal flow, the fan would be undersized by nearly half. Read at standard-air pressure without the elevation and the suction, it would still fall short of its duty in service. The elevation and the suction are small corrections on their own; with the temperature, they decide whether the fan reaches its duty.

Two refinements: inlet suction and compressibility

Inlet suction. AMCA 210 takes fan air density at the total pressure at the fan inlet. A fan pulling through a bag filter or a long suction duct sees gas below atmospheric pressure, so its density is lower than the room’s. Leave the suction out and the density is overstated.

Compressibility. Above about 2.5 kPa (around 255 mmWC) of fan pressure, the gas compresses measurably on its way through the fan, and a straight density ratio no longer holds exactly. AMCA 99 applies a compressibility coefficient, Kp, for this. We calculate it on every high-pressure duty rather than assume it.

The duty is standardised; the fan is not

Referring a duty to standard air is a way of reading the curve, not a description of the fan. The construction is chosen at the real maximum inlet temperature: materials, the heat slinger and its guard, the bearing arrangement and any cooling. And the motor is sized for the densest gas it will meet, which is usually the cold start. A hot-gas fan started cold draws far more power than it does in service, unless a damper is held closed while it comes up to speed.

What to send us

The duty-point calculator does the density arithmetic for you, and how to specify a fan duty covers the other parameters an enquiry needs.

Send us your duty point →

Jitamitra Electro Engineering · Fan-engineering notes, written for the engineer.

Sources & basis. Standard air (1.2 kg/m³ at 101.325 kPa) and the compressibility coefficient Kp: AMCA 99. Fan air density at the total pressure at the fan inlet: AMCA 210. The effect of temperature and altitude on fan pressure and power, and on motor sizing for a cold start, follows from the fan laws: at a given speed, pressure and power scale with gas density. Every figure on this page follows from the ideal-gas law for dry air (R = 287.055 J/kg·K) and the ISA barometric formula, worked as shown. Customer names and job numbers are withheld.

Questions

Frequently asked

What is standard air for a fan?

Air at 1.2 kg/m³ and a barometric pressure of 101.325 kPa, roughly 20 °C at sea level. It is the basis AMCA 99 defines, and fan curves and test results are quoted on it. Any real duty is compared with a curve only after it has been referred to that density.

Does a fan move less air at altitude?

The same volume, but less air by mass. At a given speed a centrifugal fan moves the same actual m³/h, so the volume stays the same while the kilograms of air per hour fall with the gas density, and so do the pressure it develops and the power it draws. At altitude, or in hot gas, the same fan makes less pressure than its standard-air curve shows.

Why does suction at the fan inlet change the density?

The gas entering the fan is below atmospheric pressure by the inlet suction, and lower absolute pressure means lower density. AMCA 210 takes fan air density at the total pressure at the fan inlet, so a fan pulling hard on a filter or a long duct sees thinner gas than the atmosphere outside.

Is the motor sized for the hot gas or for the cold start?

For the cold start, unless a damper is held closed while the fan comes up to speed. Cold gas is denser, so the fan draws more power until the system warms up. In the worked example on this page the cold start draws 1.56 times the hot running power.

If the duty is referred to standard air, is the fan built for standard air too?

No. Only the duty is standardised, so that it can be read off the curves. Materials, the heat slinger, the bearing arrangement and cooling are chosen at the real maximum inlet temperature.

Ready to quote?

Send us the duty point. We'll quote in 3 to 5 working days.*

Flow, static, gas temperature, application — or attach a spec, GA drawing or a multi-fan schedule. Engineer to engineer.

Get a quote → Email the desk

ISO 9001:2015 quality system · performance-tested to IS 4894 / ISO 5801 / AMCA 210 method · witnessed FAT on request.

*For our standard range. ATEX and special projects need 5 to 7 working days.